7EFD

1.77 A cryo-EM structure of Streptavidin using first 40 frames (corresponding to about 40 e/A^2 total dose)


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg31.9
r_lrange_other26.775
r_lrange_it26.566
r_dihedral_angle_4_deg24.663
r_dihedral_angle_3_deg14.664
r_scangle_it10.92
r_scangle_other10.913
r_mcangle_it9.977
r_mcangle_other9.972
r_dihedral_angle_1_deg8.687
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg31.9
r_lrange_other26.775
r_lrange_it26.566
r_dihedral_angle_4_deg24.663
r_dihedral_angle_3_deg14.664
r_scangle_it10.92
r_scangle_other10.913
r_mcangle_it9.977
r_mcangle_other9.972
r_dihedral_angle_1_deg8.687
r_scbond_it7.11
r_scbond_other7.102
r_mcbond_other6.31
r_mcbond_it6.309
r_angle_refined_deg3.023
r_angle_other_deg2.308
r_ext_dist_refined_d0.41
r_nbtor_refined0.1
r_nbd_refined0.055
r_symmetry_nbd_other0.05
r_symmetry_nbtor_other0.04
r_nbd_other0.04
r_chiral_restr0.03
r_bond_refined_d0.028
r_xyhbond_nbd_refined0.028
r_symmetry_xyhbond_nbd_refined0.028
r_bond_other_d0.027
r_symmetry_nbd_refined0.02
r_gen_planes_refined0.001
r_gen_planes_other
Sample
Streptavidin
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles153976
Reported Resolution (Å)1.77
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryD2
Map-Model Fitting and Refinement
Id1 (5N7X, 1MK5)
Refinement SpaceRECIPROCAL
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON IV (4k x 4k)
Electron Dose (electrons/Å**2)70
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONEPU
CTF CORRECTIONCTFFIND4.1.13
MODEL FITTINGMOLREP
INITIAL EULER ASSIGNMENTRELION3.1
FINAL EULER ASSIGNMENTRELION3.1
RECONSTRUCTIONRELION3.1
MODEL REFINEMENTREFMAC5.8.0272
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION