7VVO

PTH-bound human PTH1R in complex with Gs (class5)


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined47.8
r_long_range_B_other47.8
r_dihedral_angle_2_deg32.289
r_scangle_other29.718
r_mcangle_it29.18
r_mcangle_other29.178
r_mcbond_other18.423
r_mcbond_it18.421
r_scbond_it18.157
r_scbond_other18.155
RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined47.8
r_long_range_B_other47.8
r_dihedral_angle_2_deg32.289
r_scangle_other29.718
r_mcangle_it29.18
r_mcangle_other29.178
r_mcbond_other18.423
r_mcbond_it18.421
r_scbond_it18.157
r_scbond_other18.155
r_dihedral_angle_3_deg17.576
r_dihedral_angle_4_deg15.909
r_dihedral_angle_1_deg6.693
r_angle_refined_deg1.512
r_angle_other_deg1.336
r_chiral_restr0.076
r_bond_other_d0.014
r_bond_refined_d0.009
r_gen_planes_refined0.007
r_gen_planes_other0.003
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
endogenous ligand-bound the human PTH receptor in complex with Gs
Sample Components
Guanine nucleotide-binding protein G(s) subunit alpha isoforms short
Guanine nucleotide-binding protein G(I)/G(S)/G(T) subunit beta-1
Guanine nucleotide-binding protein G(I)/G(S)/G(O) subunit gamma-2
nanobody Nb35
PTHrP
Parathyroid hormone/parathyroid hormone-related peptide receptor
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles29736
Reported Resolution (Å)4.1
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)64.319
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)600
Maximum Defocus (nm)1500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONE