2YBB

Fitted model for bovine mitochondrial supercomplex I1III2IV1 by single particle cryo-EM (EMD-1876)


ELECTRON MICROSCOPY
Sample
RESPIRATORY SUPERCOMPLEX B (I1III2IV1) COMPOSED OF COMPLEX I, DIMERIC COMPLEX III AND COMPLEX IV FROM BOVINE HEART MITOCHONDRIA
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentHOMEMADE PLUNGER
Cryogen NameETHANE
Sample Vitrification DetailsVITRIFICATION 1 -- CRYOGEN- ETHANE, HUMIDITY- 70, TEMPERATURE- 95, INSTRUMENT- CUSTOM-MADE HAND PLUNGER, METHOD- ONE- SIDED BLOTTING FOR 26 - 30 SECON ...VITRIFICATION 1 -- CRYOGEN- ETHANE, HUMIDITY- 70, TEMPERATURE- 95, INSTRUMENT- CUSTOM-MADE HAND PLUNGER, METHOD- ONE- SIDED BLOTTING FOR 26 - 30 SECONDS BEFORE PLUNGING, DETAILS- SAMPLE WAS ADSORBED TO CARBON FILM FOR 30 SECONDS BEFORE BLOTTING
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles10684
Reported Resolution (Å)19
Resolution Method
Other DetailsFINAL MAP WAS CALCULATED WITH SIRT FROM COMBINED TILTED AND UNTILTED DATASETS WITH 10684 PARTICLES EACH AND OMITTING 30 PER CENT OF IMAGES WITH LOWEST ...FINAL MAP WAS CALCULATED WITH SIRT FROM COMBINED TILTED AND UNTILTED DATASETS WITH 10684 PARTICLES EACH AND OMITTING 30 PER CENT OF IMAGES WITH LOWEST CROSS CORRELATION. THIS ENTRY IS BASED ON PDBS 3IAM,3M9C,1PP9,1BGY,1OCC AND 2B4Z WHICH WERE FITTED MANUALLY INTO THE EM DENSITY MAP OF BOVINE SUPERCOMPLEX I1III2IV1. THE POSITION OF 2B4Z WAS INFERRED FROM PDB 3CX5. THE CHAIN NAMES ARE CASE SENSITIVE. CHAINS A-K AND a-k DENOTE IDENTICAL CHAINS WITHIN A DIMER. CHAINS L-X AND M-P BELONG TO DIFFERENT PROTEINS. SUBMISSION BASED ON EXPERIMENTAL DATA FROM EMDB EMD-1876.
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (3IAM, 3M9C, 1PP9, 1BGY, 1OCC, 2B4Z)
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value
Fitting Procedure
DetailsMETHOD--RIGID BODY REFINEMENT PROTOCOL--X-RAY
Data Acquisition
Detector TypeKODAK SO-163 FILM
Electron Dose (electrons/Å**2)25
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)78
Microscope ModelFEI TECNAI F30
Minimum Defocus (nm)500
Maximum Defocus (nm)6000
Minimum Tilt Angle (degrees)-50
Maximum Tilt Angle (degrees)
Nominal CS2
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification59000
Calibrated Magnification58829
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging DetailsLOW DOSE CONDITIONS. FOR RANDOM CONICAL TILT EACH AREA WAS IMAGED TWICE WITH THE FIRST IMAGE TAKEN AT A TILT ANGLE OF -45 OR -50 DEGREE
EM Software
TaskSoftware PackageVersion
MODEL FITTINGUCSF Chimera
RECONSTRUCTIONIMAGIC
RECONSTRUCTIONSPIDER
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE-FLIPPPING ON EACH PARTICLE