5OQV
Near-atomic resolution fibril structure of complete amyloid-beta(1-42) by cryo-EM
ELECTRON MICROSCOPY
Sample |
---|
Beta-amyloid protein 42 fibrils |
Specimen Preparation | |
---|---|
Sample Aggregation State | FILAMENT |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | 2.5 microL sample was applied to the grid, blotted for 2.5 s before plunging. |
3D Reconstruction | |
---|---|
Reconstruction Method | HELICAL |
Number of Particles | 127765 |
Reported Resolution (Å) | 4 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | For the even/odd test, the fibrils were split after the final reconstruction (no gold-standard). These two half sets were then refined further indepen ... |
Refinement Type | |
Symmetry Type | HELICAL |
Axial Symmetry | C1 |
Axial Rise | 2.335 |
Angular Rotation | -179.275 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | REAL | ||||
Refinement Protocol | AB INITIO MODEL | ||||
Refinement Target | Cross-correlation coefficient | ||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | FEI FALCON III (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 24 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TECNAI ARCTICA |
Minimum Defocus (nm) | |
Maximum Defocus (nm) | |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | |
Nominal Magnification | 110000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 200 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | EPU | 1.8.0.1533 |
CTF CORRECTION | SPARX | 4.0 |
INITIAL EULER ASSIGNMENT | SPARX | 4.0 |
FINAL EULER ASSIGNMENT | SPARX | 4.0 |
RECONSTRUCTION | SPARX | 4.0 |
MODEL REFINEMENT | PHENIX | 1.11.1 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION |