7L09
Cryo-EM structure of SARS-CoV-2 2P S ectodomain bound domain-swapped antibody 2G12 from masked 3D refinement
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 6VXX |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 13.855 |
f_angle_d | 1.541 |
f_chiral_restr | 0.157 |
f_bond_d | 0.014 |
f_plane_restr | 0.013 |
Sample |
---|
Severe acute respiratory syndrome-related coronavirus spike glycoprotein in complex with domain-swapped antibody 2G12 |
Sample Components |
spike glycoprotein |
antibody 2G12 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | |
Cryogen Name | ETHANE |
Sample Vitrification Details |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 222304 |
Reported Resolution (Å) | 3.1 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (6VXX) | ||||
Refinement Space | |||||
Refinement Protocol | AB INITIO MODEL | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 (6k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 66.43 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | |
Maximum Defocus (nm) | |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | Leginon | |
CTF CORRECTION | cryoSPARC | |
MODEL FITTING | ISOLDE | |
MODEL FITTING | PHENIX | |
MODEL FITTING | UCSF Chimera | |
INITIAL EULER ASSIGNMENT | cryoSPARC | |
FINAL EULER ASSIGNMENT | cryoSPARC | |
RECONSTRUCTION | cryoSPARC | |
MODEL REFINEMENT | ISOLDE | |
MODEL REFINEMENT | PHENIX | |
MODEL REFINEMENT | Coot |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION |