7MM0
Cryo-EM structure of SARS-CoV-2 spike in complex with neutralizing antibody B1-182.1 that targets the receptor-binding domain
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 7LRT |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 8.2 |
f_angle_d | 0.536 |
f_chiral_restr | 0.047 |
f_plane_restr | 0.004 |
f_bond_d | 0.003 |
Sample |
---|
SARS-CoV-2 spike in complex with neutralizing antibody B1-182.1 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | Blot for 4 seconds before plugging. |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 208776 |
Reported Resolution (Å) | 3.15 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (7LRT) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | OTHER | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details | Iterative refinement and manual model building/adjustment with Phenix and Coot. |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | OTHER | ||||||||
Electron Dose (electrons/Å**2) | 40 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 1100 |
Maximum Defocus (nm) | 2100 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 105000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | cryoSPARC | 2.15 |
CTF CORRECTION | cryoSPARC | 2.15 |
MODEL FITTING | Coot | 0.93 |
MODEL REFINEMENT | PHENIX | 1.19 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | Patch CTF of CryoSparc | 1531919 | Particles after selection of useful 2D classification |