7R8N
Structure of the SARS-CoV-2 S 6P trimer in complex with neutralizing antibody C051
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 7K90 |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 5.476 |
f_angle_d | 1.497 |
f_chiral_restr | 0.085 |
f_plane_restr | 0.011 |
f_bond_d | 0.008 |
Sample |
---|
Ternary complex of SARS-CoV-2 S 6P trimer with C051 Fabs |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | 3s blot, 0 blot force |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 134506 |
Reported Resolution (Å) | 3.55 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C3 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (7K90) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | RIGID BODY FIT | ||||
Refinement Target | |||||
Overall B Value | 64.5 | ||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 (6k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 60 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TALOS ARCTICA |
Minimum Defocus (nm) | 700 |
Maximum Defocus (nm) | |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | |
Calibrated Magnification | 45000 |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 200 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | SerialEM | |
MODEL FITTING | UCSF Chimera | |
RECONSTRUCTION | cryoSPARC | 2.15 |
MODEL REFINEMENT | PHENIX | 1.19 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | 390630 |