7ZDQ
Cryo-EM structure of Human ACE2 bound to a high-affinity SARS CoV-2 mutant
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 6M0J |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 15.1769 |
f_angle_d | 0.5392 |
f_chiral_restr | 0.0393 |
f_plane_restr | 0.0042 |
f_bond_d | 0.0024 |
Sample |
---|
Complex of Human ACE2 and SARS CoV-2 RBD |
Sample Components |
SARS CoV-2 RBD |
Angiotensin converting enzyme 2 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | Blot for 3 seconds. Wait time of 30 seconds for graphene oxide grids and 0 seconds for holey grids. |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 1010543 |
Reported Resolution (Å) | 3.2 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (6M0J) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | FLEXIBLE FIT | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 BIOQUANTUM (6k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 50 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 700 |
Maximum Defocus (nm) | 2700 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 105000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | EPU | |
CTF CORRECTION | Gctf | 1.18 |
MODEL FITTING | Coot | 0.9.6 |
INITIAL EULER ASSIGNMENT | RELION | 3.1 |
FINAL EULER ASSIGNMENT | RELION | 3.1 |
RECONSTRUCTION | RELION | 3.1 |
MODEL REFINEMENT | PHENIX | 1.19.2 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | 4312106 |