8P9Y

SARS-CoV-2 S protein S:D614G mutant in 3-down with binding site of an entry inhibitor


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg28.277
r_long_range_B_refined19.166
r_long_range_B_other19.166
r_dihedral_angle_3_deg15.576
r_dihedral_angle_4_deg14.551
r_mcangle_it5.179
r_mcangle_other5.179
r_dihedral_angle_1_deg4.165
r_scangle_other3.082
r_mcbond_it2.735
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg28.277
r_long_range_B_refined19.166
r_long_range_B_other19.166
r_dihedral_angle_3_deg15.576
r_dihedral_angle_4_deg14.551
r_mcangle_it5.179
r_mcangle_other5.179
r_dihedral_angle_1_deg4.165
r_scangle_other3.082
r_mcbond_it2.735
r_mcbond_other2.735
r_angle_refined_deg1.642
r_scbond_it1.411
r_scbond_other1.411
r_angle_other_deg1.389
r_chiral_restr0.084
r_bond_refined_d0.01
r_gen_planes_refined0.007
r_bond_other_d0.005
r_gen_planes_other0.005
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Spike glycoprotein - Severe acute respiratory syndrome coronavirus 2
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentLEICA EM GP
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles97094
Reported Resolution (Å)4.3
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)30
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TALOS ARCTICA
Minimum Defocus (nm)1000
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeOTHER
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONScipion
MODEL REFINEMENTREFMAC5.8.0158
IMAGE ACQUISITIONEPU
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION