5TAX
Structure of rabbit RyR1 (ryanodine dataset, class 1)
ELECTRON MICROSCOPY
Sample |
---|
RyR1-Cs2 complex |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | Blotted for 3-4 seconds on both sides with Whatman ashless filter paper, blot force 3, wait time 30 seconds |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 55564 |
Reported Resolution (Å) | 6.6 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | The reported resolution is for the core. The resolution of the whole assembly is 7.0 Angstrom. |
Refinement Type | |
Symmetry Type | POINT |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 50 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI POLARA 300 |
Minimum Defocus (nm) | |
Maximum Defocus (nm) | |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | |
Nominal Magnification | |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | Leginon | |
CTF CORRECTION | CTFFIND4 | 4.017 |
MODEL FITTING | Coot | 0.8.5 |
INITIAL EULER ASSIGNMENT | RELION | 1.4 |
FINAL EULER ASSIGNMENT | RELION | 1.4 |
CLASSIFICATION | RELION | 1.4 |
RECONSTRUCTION | RELION | 1.4 |
MODEL REFINEMENT | PHENIX | dev-2499 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION |