6EF3
Yeast 26S proteasome bound to ubiquitinated substrate (4D motor state)
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 5MPC |
Sample |
---|
Substrate-engaged 26S proteasome in the 4D state |
Sample Components |
Proteasome |
substrate |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | HOMEMADE PLUNGER |
Cryogen Name | ETHANE |
Sample Vitrification Details | specimens were manually blotted with Whatman #1 filter paper |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 48335 |
Reported Resolution (Å) | 4.17 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (5MPC) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | RIGID BODY FIT | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 50 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | -1000 |
Maximum Defocus (nm) | -2500 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 29000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details | images were acquired in nanoprobe mode |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | Leginon | 3.2 |
CTF CORRECTION | MotionCorr2 | 2 |
CTF CORRECTION | RELION | 2.1 |
CTF CORRECTION | CTFFIND | 4 |
CTF CORRECTION | Gctf | |
MODEL FITTING | UCSF Chimera | 1.12 |
MODEL FITTING | PHENIX | 1.11-2580 |
INITIAL EULER ASSIGNMENT | RELION | 2.1 |
FINAL EULER ASSIGNMENT | RELION | 2.1 |
RECONSTRUCTION | RELION | 2.1 |
MODEL REFINEMENT | PHENIX | 1.11-2580 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | CTF correction was performed by Relion during reconstruction | 579361 | Particles were selected using the Relion template-based particle picker |