6XCM
Structure of the SARS-CoV-2 spike glycoprotein in complex with the C105 neutralizing antibody Fab fragment (state 1)
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 6VYB |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 10.529 |
f_angle_d | 0.688 |
f_chiral_restr | 0.047 |
f_bond_d | 0.008 |
f_plane_restr | 0.004 |
Sample |
---|
SARS-CoV-2 S 2P trimer complexed with monoclonal Fab fragments from neutralizing antibody C105 |
Sample Components |
SARS-CoV-2 spike glycoprotein 2P trimer |
neutralizing antibody C105 Fab |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | 3 microliters added, blotted for 3 s with 0 blot force |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 58873 |
Reported Resolution (Å) | 3.42 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (6VYB) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | RIGID BODY FIT | ||||
Refinement Target | Correlation coefficient | ||||
Overall B Value | 90 | ||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 BIOQUANTUM (6k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 60 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 1000 |
Maximum Defocus (nm) | 2500 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 105000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details | Collected with 3x3 pattern and beam image shift |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | SerialEM | |
CTF CORRECTION | CTFFIND | 4.1 |
MODEL FITTING | UCSF Chimera | |
INITIAL EULER ASSIGNMENT | cryoSPARC | 2.14.2 |
FINAL EULER ASSIGNMENT | cryoSPARC | 2.14.2 |
CLASSIFICATION | cryoSPARC | 2.14.2 |
RECONSTRUCTION | cryoSPARC | 2.14.2 |
MODEL REFINEMENT | PHENIX | 1.17 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION |