6GV4
High-resolution Cryo-EM of Fab-labeled human parechovirus 3
ELECTRON MICROSCOPY
Sample |
---|
Human parechovirus type 3 in complex with fabs from AT12-015 |
Sample Components |
Human parechovirus type 3 |
fabs from AT12-015 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | HOMEMADE PLUNGER |
Cryogen Name | ETHANE |
Sample Vitrification Details | We could not control humidity during plunging. It was ambient humidity. Blot for 1 s before plunging. |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 74927 |
Reported Resolution (Å) | 2.8 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | I |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | REAL | ||||
Refinement Protocol | OTHER | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details | Initial model was generated in I-TASSER and SWISSMODEL using 4z92 and 4udf as reference. Initial rigid fit of the model to the map was done in UCSF Ch ... |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | FEI FALCON II (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 48 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 500 |
Maximum Defocus (nm) | 2500 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 75000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | RELION | 2.0 |
IMAGE ACQUISITION | RELION | 2.0 |
MODEL FITTING | UCSF Chimera | 1.12 |
INITIAL EULER ASSIGNMENT | RELION | 2.0 |
FINAL EULER ASSIGNMENT | RELION | 2.0 |
CLASSIFICATION | RELION | 2.1 |
RECONSTRUCTION | RELION | 2.1 |
MODEL REFINEMENT | MDFF | |
MODEL REFINEMENT | Coot | 0.8.8 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | GCTF was used to estimate ctf | 217212 | automatic particle selection in RELION using template generated from manually selected particles |