7RMH
Substance P bound to active human neurokinin 1 receptor in complex with miniGs399
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 6HLP |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 13.4167 |
f_angle_d | 0.746 |
f_chiral_restr | 0.0497 |
f_plane_restr | 0.0054 |
f_bond_d | 0.0037 |
Sample |
---|
Substance P bound to Neurokinin1 receptor-miniGs399 complex |
Sample Components |
Substance P |
Substance-P receptor |
miniGs399 |
Guanine nucleotide-binding protein G(I)/G(S)/G(T) subunit beta-1/gamma-2 |
Nanobody 35 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 288659 |
Reported Resolution (Å) | 3.1 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (6HLP) | ||||
Refinement Space | |||||
Refinement Protocol | |||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 (6k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 49.4 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | |
Maximum Defocus (nm) | |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | |
Nominal Magnification | |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | cryoSPARC | |
IMAGE ACQUISITION | EPU | 2.1 |
CTF CORRECTION | cryoSPARC | |
MODEL FITTING | PHENIX | |
INITIAL EULER ASSIGNMENT | cryoSPARC | |
FINAL EULER ASSIGNMENT | cisTEM | |
CLASSIFICATION | RELION | |
RECONSTRUCTION | cisTEM | |
MODEL REFINEMENT | PHENIX |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | 4865341 |