8G3P

N2 neuraminidase of A/Hong_Kong/2671/2019 in complex with 4 FNI9 Fab molecules


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg30.217
r_long_range_B_refined19.425
r_long_range_B_other19.425
r_dihedral_angle_4_deg17.162
r_scangle_other12.857
r_dihedral_angle_3_deg11.651
r_mcangle_it10.367
r_mcangle_other10.367
r_dihedral_angle_1_deg8.373
r_scbond_it7.775
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg30.217
r_long_range_B_refined19.425
r_long_range_B_other19.425
r_dihedral_angle_4_deg17.162
r_scangle_other12.857
r_dihedral_angle_3_deg11.651
r_mcangle_it10.367
r_mcangle_other10.367
r_dihedral_angle_1_deg8.373
r_scbond_it7.775
r_scbond_other7.774
r_mcbond_it6.636
r_mcbond_other6.635
r_angle_refined_deg1.693
r_angle_other_deg1.391
r_chiral_restr0.087
r_bond_refined_d0.01
r_gen_planes_refined0.008
r_gen_planes_other0.002
r_bond_other_d
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
N2 neuraminidase of A/Hong_Kong/2671/2019 in complex with 4 FNI9 Fab molecules
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles162364
Reported Resolution (Å)2.5
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC4
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)52.32
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)1200
Maximum Defocus (nm)1800
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION